GB-GS Open

Integrated metal / plastic fuel tank

Base frame provided with feet for easy handling

Moving and rotating parts protections against accidental contacts

Heavy duty anti-vibration mountings

Browse Categories

Filters

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW35Y

FREQUENCY: 60 Hz
VOLTAGE: 380 V
PHASE: 3
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 49.50 kVA
PRIME POWER PRP: 45.66 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Tier 4 Interim
ALTERNATOR: Mecc Alte

See details

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW35Y

FREQUENCY: 60 Hz
VOLTAGE: 440 V
PHASE: 3
POWER RANGE: c) 50-100 kVA
EMERGENCY STANDBY POWER ESP: 52.49 kVA
PRIME POWER PRP: 47.17 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Tier 4 Interim
ALTERNATOR: Mecc Alte

See details

GBW OPEN DSE.jpg - [4883]

GBW-45Y (ALT. P)

FREQUENCY: 50 Hz
VOLTAGE: 400 V
PHASE: 3
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 44.76 kVA
PRIME POWER PRP: 42.49 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage II
ALTERNATOR: Pramac

See details

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW45P

FREQUENCY: 50 Hz
VOLTAGE: 400 V
PHASE: 3
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 49.50 kVA
PRIME POWER PRP: 45.22 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW45P

FREQUENCY: 60 Hz
VOLTAGE: 240 V
PHASE: 1
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 41.00 kVA
PRIME POWER PRP: 40.00 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW45P

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 3
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 49.50 kVA
PRIME POWER PRP: 45.22 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW45Y

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 3
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 45.33 kVA
PRIME POWER PRP: 43.03 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage II
ALTERNATOR: Mecc Alte

See details

GBW OPEN DSE.jpg - [4883]

GBW-45Y (Alt. M)

FREQUENCY: 50 Hz
VOLTAGE: 400 V
PHASE: 3
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 45.33 kVA
PRIME POWER PRP: 43.03 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage II
ALTERNATOR: Mecc Alte

See details

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW45P

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 1
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 31.00 kVA
PRIME POWER PRP: 29.00 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GBW OPEN other version from 400V DSE.jpg - [5348]

GBW45Y

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 1
POWER RANGE: b) 25-50 kVA
EMERGENCY STANDBY POWER ESP: 31.00 kVA
PRIME POWER PRP: 29.00 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage II
ALTERNATOR: Mecc Alte

See details

13 / 43