GRW22Y/S5
GAMME DE PUISSANCE:
a) <25 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
19.3
kVA
PUISSANCE NOMINALE PRP:
18.3
kVA
FABRICANT DU MOTEUR:
Yanmar
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage V
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
GRW35Y
GAMME DE PUISSANCE:
b) 25-50 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
38.2
kVA
PUISSANCE NOMINALE PRP:
34.4
kVA
FABRICANT DU MOTEUR:
Yanmar
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage IIIA
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR EPA TIER 60HZ (EPA):
Tier 4 Interim
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
GRW50Y
GAMME DE PUISSANCE:
b) 25-50 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
47.0
kVA
PUISSANCE NOMINALE PRP:
42.4
kVA
FABRICANT DU MOTEUR:
Yanmar
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage IIIA
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR EPA TIER 60HZ (EPA):
Tier 4 Interim
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
SELECTEUR DOUBLE FRÉQUENCE (50/60 HZ):
DFS
Υ400/230V 50HzΥ480/277V 60Hz
SELECTEUR DE TENSION:
VSS
GRW60I/S5
GAMME DE PUISSANCE:
c) 50-100 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
61.0
kVA
PUISSANCE NOMINALE PRP:
60.0
kVA
FABRICANT DU MOTEUR:
FPT
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage V
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
GRW67P
GAMME DE PUISSANCE:
c) 50-100 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
66.0
kVA
PUISSANCE NOMINALE PRP:
60.0
kVA
FABRICANT DU MOTEUR:
Perkins
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage IIIA
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR EPA TIER 60HZ (EPA):
Tier 3
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
GRW80I/S5
GAMME DE PUISSANCE:
c) 50-100 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
88.0
kVA
PUISSANCE NOMINALE PRP:
80.0
kVA
FABRICANT DU MOTEUR:
FPT
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage V
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
SELECTEUR DOUBLE FRÉQUENCE (50/60 HZ):
DFS
Υ400/230V 50HzΥ480/277V 60Hz
SELECTEUR DE TENSION:
VSS
GRW95P
GAMME DE PUISSANCE:
c) 50-100 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
93.2
kVA
PUISSANCE NOMINALE PRP:
84.5
kVA
FABRICANT DU MOTEUR:
Perkins
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage IIIA
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR EPA TIER 60HZ (EPA):
Tier 3
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
SELECTEUR DOUBLE FRÉQUENCE (50/60 HZ):
DFS
Υ400/230V 50HzΥ480/277V 60Hz
SELECTEUR DE TENSION:
VSS
GRW100I/S5
GAMME DE PUISSANCE:
d) 100-150 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
104.3
kVA
PUISSANCE NOMINALE PRP:
100.0
kVA
FABRICANT DU MOTEUR:
FPT
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage V
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
GRW115P
GAMME DE PUISSANCE:
d) 100-150 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
110.0
kVA
PUISSANCE NOMINALE PRP:
100.0
kVA
FABRICANT DU MOTEUR:
Perkins
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage IIIA
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR EPA TIER 60HZ (EPA):
Tier 3
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
:
GRW150I/S5
GAMME DE PUISSANCE:
e) 150-250 kVA
FRÉQUENCE:
50
Hz
TENSION:
400/230
V
PUISSANCE SECOURS ESP:
165.0
kVA
PUISSANCE NOMINALE PRP:
150.0
kVA
FABRICANT DU MOTEUR:
FPT
ÉMISSIONS DES GAZ D'ÉCHAPPEMENT OPTIMISÉES POUR 97/68 50HZ (COM):
Stage V
À COMMANDER AVEC LES ÉQUIPEMENTS (SI BESOIN):
: